3N filter reactor of low pressure

3N reactor can withstand the loss generatedby the fundamental current and harmonic current, and the reactor will notexceed the temperature range of insulating material in the conventionalenvironment. The reactor has a sufficiently high linearity to withstand theswitching of the capacitor, and it will not cause saturation due to a lot ofharmonic distortion. The design iron core reactor to prevent magnetic fluxleakage can ensure lower losses and noise levels, and provide the best solutionfor the app

 

Ultra-low-loss

strong anti-harmonic

Reactance valueprecision

High linearity

Simple installation

Long life

With temperatureprotection

 

lication of the product.Process &structure

3N reactor provided by AKSON is the corereactor, which can eliminate the inductance error among the three-phase by usinghigh precision laminations, to ensure the tuning accuracy of the reactor.Winding machine is controlled by computer, with winding of copper or aluminum.All product is injected with polyethylene resin in vacuum environment, and everyone phase will be finely adjusted.

Production process is executed by theregulations of DIN, EN, ISO9001.

Design standards

It is difficult to predict the actualrunning conditions of the reactor, so we designed reactors according to the harshestoperating conditions, and executed by the regulations of internationalstandards ICE60289.

Inductance error                        Rated inductance LN ± 3%

Fundamental current                1.06ICN or 1.10ICN (Representing the case when OverVoltage of 1.06 or 1.10)

Harmonic voltage distortion   Based on the rated voltage UN UH3 = 0.5% UH5= UH7 = 5.0%

Current Ith                                   1.05Irms(Associated with running harsh environment and capacitor aging)

linear current of Iron core                 ILin 1.20 Σ I1 ... I7 1.7IN(Associatedwith various harmonic load)

Technical parameters

Ambient temperature     Below 40

Rated voltage                    230 ~ 690V, 50/60Hz

Output power             5 ... 100kvar

Reactance rate          5%, 5.5%, 5.67%, 6%, 7%, 8%, 12.5%​​, 14%

Overload capacity        1.8IN

Linearity                     20IN

Degree of protection                     I

Package                     IP00

Cooling method                Naturalcooling

Winding material                Copperor aluminum,

Dipping          Polyesterresin, Class F

Insulation level              thewinding - core 3kV

Temperature Monitoring              Normallyclosed contact 120

Parameter errors             ± 3%

Ambient temperature            Below40

Technology standard     VDE0550/0532, IEC76

Selection Table

Model

Capacity

Reactance coefficient

Weight

Size

LWH

And outlet

Temperature Monitoring

Note 1 model problems, please contact us

Installation dimensions

Model

Note: 1. It is available to provide othervoltage level of the three-phase or single-phase reactor products andinformation.

2. For the same voltage level, thereactor with reactance ratio of 14% is same with the reactor with reactanceratio of 7% on the installation dimensions.