LcaruSy powermonitoring system
LcaruSy power monitoring system is a set ofmonitoring system designed to help group of users to reduce power-off time,improve energy efficiency, and the system can provide reliable, flexible andhigh-performance power scheme. With the guarantee of high real-time performanceand reliability at the same time, LcaruSy can handle needs of the user from simpleto complex. Friendly interface and easy-to-use configuration tool can make thatyou will be well aware of the power system.
The LcaruSy power monitoring system is anopen, modular system, which is based on the latest technology, and the system perfectintegrate with the secondary equipment of AKSON electrical. The system canmonitor ,protect and control the power system equipment in case of the normaland failure , in order to achieve a high degree of continuous, stable managementof power supply and optimized grid device.
Latest system architecture is used in LcaruSypower monitoring system to ensure reliable, efficient, and the integrity of thedata. Complex user permissions are running through the system interface, toguarantee the safety of the control. Based on object, the library of standarddrawings and symbols, the direct command and control can improve the efficiencyof the operator.
LcaruSy power monitoring system can be onsale as a complete solution, which has been related to an independent andcomplete package with the integration of agreement, drive and various functions.LcaruSy, the highly integrated system, can be applied directly.
LcaruSy power monitoring system is consistof the modular products of complete series and high-quality independentequipment, and these products are electromechanical compatible, which provide avariety of options for electrical installation design and implementation. Thesystem is consisting of the protection, control and drives, power strips,cabinet installation and the lateral communication protocol.
LcaruSy power monitoring system can be usedfor a variety of electrical power distribution system, and it will connectmultiple communication devices to one or more monitoring stations, which willform a communication network. LcaruSy power monitoring system mainly consistsof three parts:
System management: management functions bythe computer and software
Communication interface: communicationprotocol conversion, data communication
Site monitoring layer: data acquisition,communication, command implementation in site
LcaruSy power monitoring system can beadapted to the special needs of each implementation of on-site, and by virtueof the system architecture and the technical team of professional technical,AKSON Electric can provide solutions adapted to their needs of all users. Somespecial features that can be customized:
The device monitoring of third-party
Reliable redundant architecture
The hot / backup redundant I / O configuration
Distributed
Self-healing ring-based communication
Main / backup server configuration
The station topology map of thedistribution of power monitoring system of LcaruSy
Switching station
High voltage microcomputer protection relay
DC power system
485 Field bus
Optical
The workstation System monitoring station
Switchboard
Communication FEP
Database server
Web server
Streaming media server
Optical fiber
Printer
Report printing
Monitoring data printing
Fault log Print
Monitoring information Print
Power station
High voltage microcomputer protection relay
Low-voltage network power meter
DC power system
Transformer temperature controller
485 Field bus
Optical
Information inquiry
Modern graphical display
Alarm information inquiry
Monitoring information query
Data acquisition
High-voltage protection devices acquisition
Switch state acquisition
Low parameter acquisition
Transformer Data Acquisition
Control
Switch control
FM control
Alarm settings
Configuration Information inquiry Statements Monitoring Desk Video Multi-screen To support the various mobile terminals
Control services web services webserver Browser queries Remote Access The function
Collection service Data analysis services DataAnalysis Statistics, analysis, graphical
Communication Library Protocol library Primitives library
Communication Control
Data acquisition layer
High voltage microcomputer protection relay
End-product characteristics:
Powerful function, sophisticatedtechnology, beautiful appearance, and cost effective. The features of Highintegration, protection configuration is complete, anti-interference ability,less power consumption, and resistance to harsh environments
Monitoring range of the system:
State of the high voltage switch position,the position of the state of the withdrawable unit, spring energy status,running analog of the high voltage circuit such as voltage, current, electric energyand protection action, alarms and other information.
Network power meter of low-voltage
End-product characteristics:
Network Power Meter is designed for powersystems, utilities and other power monitoring needs. All common powerparameters can be high-precision measured
Monitoring range of the system:
State of the switch’s position, analog valueof the voltage, current, electrical energy of low voltage, remote control ofincoming and bus coupler circuit
DC power system
End-product characteristics:
Monitoring host is of a highly integrated,containing functions of insulation monitor, battery inspection, the groundingline, battery activation the silicon chain regulator, microcomputer centralsignal. The DC panel system provides powerful features for remote monitoringand control.
Monitoring range of the system:
Closing bus, output voltage of control bus,current, battery voltage, battery temperature, charger running state, Closingbus, controlling bus and insulation monitoring for each loop
Transformer temperature controller
End-product characteristics:
Tour detection and temperature indication,over-temperature alarm, ultra-high automatic tripping, sensor failure alarm, nofan control and other functions
Monitoring range of the system:
Temperature monitoring of three-phase lineof the transformer, state of fan turned on and protection action related to thetemperature of the transformer, alarm and etc.